HP J9263A#ABB

PROCURVE SWITCH 6600-24G/WW CPNT . UK

Identificador:39344
Marca:HP
P/N:J9263A#ABB
EAN:0884420075783
Disponibilidad:
Stock:No Disponible
PROCURVE SWITCH 6600-24G/WW CPNT EN
-
3267.5
* precio sin IVA  Informativo  Descatalogado

HP ProCurve 6600-24G Switch

PROCURVE SWITCH 6600-24G/WW CPNT EN

Garantía
Warranty: Lifetime warranty: for as long as you own the product, with next-business-day advance replacement (available in most countries).
Más información: ProCurve 6600-24G
Productos relacionadosVer
Ficha técnica
ReferenciaHP J9263A#ABB
Maximă de rată de transfer de date1 Gbit/s
Duplex complet
Timp de întârziere< 3.7 µs
Capacitatea de comutare48 Gbit/s
Mărimea tabelei de adresare10000 entries
Sprijin de control al debitului
Link Aggregation
DHCP client
IGMP snooping
De tip SwitchManaged
Platforma de managementHP ProCurve Manager Plus; HP ProCurve Manager (included); command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C).
Protocoale de reţea acceptateRFC 1591 DNS (client); HTML and telnet management; IEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058; RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP;
RFC 4675 RADIUS VLAN ﹠ Priority; RFC 3376 IGMPv3 (host joins only);
RFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License); RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4443 ICMPv6; RFC 4541 IGMP ﹠ MLD Snooping Switch; RFC 4861 IPv6 Neighbor Discovery; RFC 4862 IPv6 Stateless Address Auto-configuration; RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB; RFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA; RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF); IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting.
Cantitatea Porturi24
Tehnologia de conectareWired
Memorie şi procesorFreescale PowerPC 8540 @ 666 MHz, 4 MB flash, 256 MB compact flash, 256 MB DDR SDRAM; packet buffer size: 18 MB QDR SDRAM total (for all 1-GbE ports).
ProcesorPowerPC 8540
Viteza procesorului666 MHz
Memorie internă256 MB
Memorie volatilă256 MB
Throughput35700000 pps.
Raft pentru montat echipamente19"
Dimensiuni(LxAxI)44.25 x 54.61 x 4.32 cm
Greutate7580 g
Care pot fi stivuite
Power over Ethernet (PoE) Suport
Frecvenţa de intrare50/60 Hz
Tensiunea de intrare100 -120 / 200 - 240 V
Tipul sursei de energie1 x J9269A
Conformităţi industriale standardGeneric: EN 55024, CISPR 24; ESD: IEC 61000-4-2; Radiated: IEC 61000-4-3; EFT/Burst: IEC 61000-4-4; Surge: IEC 61000-4-5; Conducted: IEC 61000-4-6; Power frequency magnetic field: IEC 61000-4-8; Voltage dips and interruptions: IEC 61000-4-11; Harmonics: EN 61000-3-2, IEC 61000-3-2; Flicker: EN 61000-3-3, IEC 61000-3-3.
Tip de sasiu1U height
MontajTelco rack: Mounts in an EIA-standard 19-in. 2-post telco rack or equipment cabinet; horizontal surface mounting only. Rack kit: Rack rails are required for mounting in HP 10000 Series 4-post racks.
Administrate prin telecomandă(de la distanţă)command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Mărime54.6 x 44.2 x 4.32. (21.5 x 17.42 x 1.7.)
Porturi de intrare/ieşire20x 10/100/1000
4x RJ-45
Emisiuni de presiune acusticăPower: 71 dB; Pressure: 62.3 dB ISO 7779, ISO 9296 dB
Puterea consumată124.6 W
Cerinţe de energie100 -120 VAC / 200 -240 VAC; 50 /60 Hz
The switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz.
Disiparea căldurii425 BTU/hr (448.38 kJ/hr)
Sloturi de alimentare electrică a deschide2
SiguranţăCSA 22.2 No. 60950; EN 60950/IEC 60950; UL 60950.
Emisiuni electromagneticeFCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A.
Interval relativ operaţional de umiditate15 - 80 %
Interval de temperatură de funcţionare (T-T)5 - 40 °C
Altitudinea de operare> 3 Km
Gama de stocare umiditate relativă15% to 90% @ 70ºC
Intervalul de temperatură pentru depozitare-40 - 158ºF
-40 - 70 °C
Sursa de date-sheetICEcat.biz
Compatibilitate electromagneticăFCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A.
Imunitatea electromagneticăEN 55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN 61000-3-2, IEC 61000-3-2; EN 61000-3-3, IEC 61000-3-3
Management nume de produsHP ProCurve Manager Plus; HP ProCurve Manager (included)
Protocoale acceptateRFC 1591 DNS (client); HTML and telnet management
RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB
MIBs
IP multicast
IEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP (Premium License); RFC 4675 RADIUS VLAN ﹠ Priority
RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2461 IPv6 Neighbor Discovery; RFC 2462 IPv6 Stateless Address Auto-configuration; RFC 2463 ICMPv6; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4541 IGMP ﹠ MLD Snooping Switch
IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3176 sFlow; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3; XRMON
Network management
General protocols
Security
IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv2 Secure Shell
IPv6
Device management
OSPF
RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF)
RFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA
RFC 3376 IGMPv3 (host joins only); RFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License)
Nota zgomotului acusticISO 7779, ISO 9296
Altitudine de operare (Imperial)up to 10000 ft.
Accesorii electriceThe switch automatically adjusts to any voltage between 100-120 and 200-240 volts and either 50 or 60 Hz
Switch viteza de ţesătură48 Gbps
Fan tray slots1
Fan trays1 x J9271A
Opiniones de usuarios:
Su opiniónAñadir opinión
Valoración ☆☆☆☆☆ (Sin valoración)
Opiniones y comentarios, HP J9263A#ABB