Ficha técnica
ReferenciaHP J8165A
Latency<13.3 µs (LIFO), <12 µs (LIFO)
Routing/switching capacity13.6 Gbps
Address table size8,000 entries
Management featuresProCurve Manager (included); ProCurve Manager Plus; command line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
CommunicationsRFC 783 TFTP; RFC 951 BootP; RFC 1542 BootP; RFC 854 Telnet; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 SNTP; IEEE 802.3x Flow Control; DHCP Relay; RFC 3046 DHCP Relay Agent Information Option 82; RFC 2236 IGMP v1/v2/v3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol; IEEE 802.1AB Link Layer Discovery Protocol; ANSI/TIA-1057 LLDP Media Endpoint Discovery (MED); RFC 1492 TACACS+; SSHv1/SSHv2 Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; 802.3af Power over Ethernet; IEEE 802.1Q GVRP; IEEE 802.1p Priority; SNMPv1/v2c/v3; HTML and telnet management; RFC 1493 Bridge MIB; RFC 1213 MIB II; RFC 2096 IP Forwarding Table MIB; RFC 2737 Entity MIB; RFC 2863 Evolution of Interface; RFC 2665 Ethernet MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3164 Syslog; RFC 2021 RMON probe configuration (RMON v2); RFC 2668 802.3 MAU MIB; RFC 2613 SMON; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2618 RADIUS Client MIB, RFC 783 TFTP; RFC 951 BootP; RFC 1542 BootP; RFC 854 Telnet; RFC 768 UDP; RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 2030 SNTP; IEEE 802.3x Flow Control; DHCP Relay; RFC 3046 DHCP Relay Agent Information Option 82; RFC 2236 IGMP v1/v2/v3; IEEE 802.1D Spanning Tree; IEEE 802.1w Rapid Convergence Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol; IEEE 802.1AB Link Layer Discovery Protocol; ANSI/TIA-1057 LLDP Media Endpoint Discovery (MED); RFC 1492 TACACS+; SSHv1/SSHv2 Secure Shell; Secure Sockets Layer (SSL); IEEE 802.1X Network Login; 802.3af Power over Ethernet; IEEE 802.1Q GVRP; IEEE 802.1p Priority; SNMPv1/v2c/v3; HTML and telnet management; RFC 1493 Bridge MIB; RFC 1213 MIB II; RFC 2096 IP Forwarding Table MIB; RFC 2737 Entity MIB; RFC 2863; Evolution of Interface; RFC 2665 Ethernet MIB; RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3164 Syslog; RFC 2021 RMON probe configuration (RMON v2); RFC 2668 802.3 MAU MIB; RFC 2613 SMON; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2618 RADIUS Client MIB
Memory and processorProcessor type and speed: Motorola Power PC MPC8245, 266 MHz; Flash capacity: 8 MB; SDRAM: 32 MB
Processor typeProcessor
Throughput10.1 million pps
Rack mountingMounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Dimensions W x D x H44.25 x 45.8 x 4.45 cm
Weight7400 g
Input current7.5 / 3.5 A
Input frequency50 / 60 Hz
Input voltage100-240 VAC
Compliance industry standardsEN55024, CISPR 24; EN: EN55024, CISPR 24; ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD; Radiated: IEC 61000-4-3; 3V/m; EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line); Surge: IEC 61000-4-5; 1 kV/2 kV AC; Conducted: IEC 61000-4-6; 3V; Power frequency magnetic field: IEC 61000-4-8; 1A/m, 50 or 60 Hz; Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods; Harmonics: EN61000-3-2, IEC61000-3-2; Flicker: EN61000-3-3, IEC61000-3-3, EN 55024/CISPR-24; ESD: IEC 61000-4-2, 4 kV CD, 8 kV AD; Radiated: IEC 61000-4-3, 3V/m; EFT/Burst: IEC 61000-4-4, 1.0 kV (power line), 0.5 kV (signal line); Surge: IEC 61000-4-5, 1 kV/2 kV AC; Conducted: IEC 61000-4-6, 3V; Power frequency magnetic field: IEC 61000-4-8, 1A/m, 50 or 60 Hz; Voltage dips and interruptions: IEC 61000-4-11, >95% reduction, 0.5 period, 30% reduction, 25 periods; Harmonics: EN 61000-3-2/IEC 61000-3-2; Flicker: EN 61000-3-3/IEC 61000-3-3
Chassis type1
Mount typeMounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Remote administrationcommand-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
Size18.03 x 17.42 x 1.75.
I/O ports48 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX); 1 RS-232C DB-9 console port; 2 dual-personality ports - each port can be used as either an RJ-45 10/100/1000 port (IEEE 802.3 Type 10Base-T; IEEE 802.3u Type 100Base-TX; IEEE 802.3ab 1000Base-T Gigabit Ethernet) or an open mini-GBIC slot (for use with mini-GBIC transceivers)
Weight16.31 lb., yes
Product weight (fully loaded)7.4 kg
Product weight (fully loaded)16.31 lb
Acoustic pressure emissionsPower: 53 dB; DIN 45635T.19 per ISO 7779 dB
Power consumption631 W
Power availability6.4 A
Heat dissipation2,288 BTU/h
Power requirements100–120 VAC/200–240 VAC; 50/60 Hz, 100-120 VAC/200-240 VAC; 50/60 Hz
SafetyCSA 22.2 No. 950; cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition; UL 60950
Electromagnetic emissionsFCC Class A; EN 55022/CISPR-22 Class A; VCCI Class A
Operating relative humidity range15-95 %
Operating altitude4600 m
Operating temperature range (T-T)0 - 50 °C
Storage temperature range (T-T)-40-70 °C
Non-operating humidity15-95 %
Operating maximum wet bulb temperature (Fahrenheit)32 - 122º
Electromagnetic compatibilityFCC Class A; EN 55022/CISPR-22 Class A; VCCI Class A
Features 02Rapid Convergence Spanning Tree Protocol (802.1w)Rapid Convergence Spanning Tree Protocol (802.1w): increases network uptime through faster recovery from failed links., Power over Ethernet (IEEE 802.3af) compliant (ProCurve 2650-PWR / 2626-PWR / 2600-8-PWR)Power over Ethernet (IEEE 802.3af) compliant (ProCurve 2650-PWR/ProCurve 2626-PWR/ProCurve 2600-8-PWR): provides up to 15.4 W per port to power IP phones, wireless access points, Web cameras, and more (ProCurve 2650-PWR may require an external power supply to provide full 15.4 W for all 48 PoE-ready ports), Port securityPort security: prevents unauthorized access using MAC address lockdown., Dual-personality functionalityDual-personality functionality: two 10/100/1000 ports or mini-GBIC slots for optional fiber connectivity such as Gigabit-SX, -LX, or -LH., Basic IP routingBasic IP routing: enables automatic routing with up to 16 external routes—including one default route—in IP networks., Multiple user authentication methods - IEEE 802.1XMultiple user authentication methods - IEEE 802.1X: industry-standard way of user authentication using an 802.1X supplicant on the client in conjunction with a RADIUS server, 802.3ad Link Aggregation Control Protocol (LACP) and ProCurve trunking802.3ad Link Aggregation Control Protocol (LACP) and ProCurve trunking: support up to 6 trunks, each with up to 4 links (ports) per trunk; trunking across modules is supported, Spanning Tree Protocol (IEEE 802.1D)Spanning Tree Protocol (IEEE 802.1D): provides redundant links while preventing network loops, TACACS+TACACS+: eases switch management security administration by using a password authentication server., 13.6 Gbps (ProCurve 2650 and 2650-PWR)/9.6 Gbps (ProCurve 2626, 2626-PWR, 2600-8-PWR) backplane13.6 Gbps (ProCurve 2650 and 2650-PWR)/9.6 Gbps (ProCurve 2626, 2626-PWR, 2600-8-PWR) backplane: wire-speed non-blocking architecture for low-latency throughput
Electromagnetic immunityEN55024, CISPR 24; EN55024, CISPR 24; IEC 61000-4-2; IEC 61000-4-3; IEC 61000-4-4; IEC 61000-4-5; IEC 61000-4-6; IEC 61000-4-8; IEC 61000-4-11; EN61000-3-2, IEC61000-3-2; EN61000-3-3, IEC61000-3-3
Management product nameProCurve Manager Plus; ProCurve Manager (included)
Protocol supportedHTML and telnet management, IEEE 802.1AB Link Layer Discovery Protocol (LLDP); RFC 2819 Four groups of RMON: 1 (statistics), 2 (history), 3 (alarm) and 9 (events); RFC 3164 BSD syslog Protocol; ANSI/TIA-1057 LLDP Media Endpoint Discovery (LLDP-MED); SNMPv1/v2c/v3, Network Management, IP Multicast, IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3af Power over Ethernet; IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; RFC 826 ARP; RFC 854 TELNET; RFC 951 BOOTP; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 3046 DHCP Relay Agent Information Option, RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2863 The Interfaces Group MIB, IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2138 RADIUS Authentication; RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv1/SSHv2 Secure Shell, Security, General Protocols, MIBs, Device Management, RFC 2236 IGMPv2
Acoustic pressure emissions (ISO standard)DIN 45635T.19 per ISO 7779
Operating altitude (imperial)up to 15000 ft.
Centrino technologyMotorola PowerPC MPC8245 @ 266 MHz, 8 MB flash, 32 MB SDRAM