HP AF508A

PWR MONITOR 3PH 16A ACCS INTL SNGL PDU

Identifier:36223
Brand:HP
P/N:AF508A
EAN:8827804721052
Availability:
Stock:No Disponible
PWR MONITOR 3PH 16A ACCS INTL SNGL PDU
-
369.33
* price without VAT  Informative  Discontinued

HP Single Input 3 Phase 16A Monitored Power Distribution Unit

PWR MONITOR 3PH 16A ACCS INTL SNGL PDU

Overview
The monitored vertical rack mount power distribution units, provides both single and three-phase monitored power, as well as full-rack power utility ranging from 4.9 kVA up to 22 kVA. Available PDU's include full rack models with 39 receptacles or with 78 receptacles, and half rack versions, 3 phase models with 12 C-19 receptacles, and single phase models with 24 C-13 and 3 C-19 receptacles.

Features
Performance

⁍ Performance: With both single-phase or three-phase power and output power ranging from 4.9 kVA up to 22.1 kVA per PDU, the amount of equipment connected to a single PDU is significantly increased over existing PDU products available. Additional customer choice of single feed or dual feed models allow for power redundancy as well as increased outlet count (Full rack vertical mount models with either 39 receptacles per single feed model, or 78 receptacles per dual feed model; half rack vertical mount models with twelve C-19 receptacles for 3 phase versions, and single phase versions have 24 C-13 and three C19 receptacles).


Customer choice

⁍ Customer choice: Full rack vertical PDU: Models consist of single feed or dual feed models allowing for power redundancy as well as increased outlet count (either 39 receptacles per single feed model or 78 receptacles per dual feed model); Along with the product choices comes the requirement to be sure and have your data center able to accommodate the correct input power. Below are the types of input plugs available on the full rack vertical PDU models; Half rack vertical PDU: Models consist of single feed model with twelve C-19 outlets. Along with the product choices comes the requirement to be sure and have your data center able to accommodate the correct input power. Below are the types of input plugs on the available on the half rack vertical PDU models.


Monitoring

⁍ Monitoring: The front panel has a two-digit, seven segment LED digital display, which shows the current in each circuit breaker, a scroll button to scroll through values, and six LEDs, which indicate current overloads and voltage out of range conditions. Current monitoring consists of two digit RMS current, with load segment LEDs reporting three different conditions (normal 0-80%; caution 80-102%; warning > 102%). Voltage monitoring measures over voltage and under voltage on any output load segment.


Color-coded load segments

⁍ Color-coded load segments: Both the front panel receptacles and circuit breakers are color coded by load segment for easy and quick identification and matching. Load segments are also spread across the length of the PDU for equal distribution in a rack. Flat rocker circuit breakers provide additional security by preventing accidental shut off (smooth/flush to PDU surface when on).

Garantía
Service ﹠ support options: Options HP Care Pack services provide a range of life cycle support options that let you choose the service levels that meet your business requirements, from basic to mission-critical. A full range of HP Care Pack hardware and software services are available including: Installation and start up; Education courses; Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7 days call window with options including 4-hour response or 6-hour Call To Repair; Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and VMware-based IT solutions helping to deliver high level of application availability, response times range from 30 mins for critical problems to 2 hours; System Management, Performance Services and Mission Critical Support Solution
Warranty: limited 3-year warranty
Más información: Single Input 3 Phase 16A Monitored Power Distribution Unit
Productos relacionadosVer
Ficha técnica
ReferenciaHP AF508A
Management platformMonitor power locally and remotely (with optional SNMP module)
Maximum current16 (three phase) or 32 (one phase)
Source data-sheetICEcat.biz