Referencia | HP AK318A |
---|
Antal processorer | 1 pcs |
---|
CPU | Single-Core Intel Celeron 420 1.6 GHz [320GB SATA model]; Dual-Core Intel Pentium E2160 1.8 GHz [1TB SATA, 2TB SATA, and 584GB SAS models] |
---|
2nd level cache | 512KB (1 x 512KB) (L2) [320 SATA model]; 1 (1x1) (L2) [1TB SATA, 2TB SATA, ﹠ 584 SAS models] |
---|
Lagerkapacitet | 584 Raw Internal SAS, 2 TB Raw Internal SATA |
---|
Maximum intern hukommelse | 8 GB |
---|
Intern hukommelse, teknologi | 1GB (1 x 1GB) PC2-6400 unbuffered DDR2 ECC 800MHz; Included |
---|
Netværk features | Embedded NC105i PCIe Gigabit Ethernet Server Adapter |
---|
Redundant strømforsyning | N/A |
---|
Dimensioner (W x H xD) | 41.63 x 50.09 x 56.79 cm |
---|
Vægt | 10500 g |
---|
Kompatible operativsystemer | Microsoft Windows Storage Server 2003 Release 2, Workgroup x64 Edition [320GB SATA model]; Microsoft Windows Storage Server 2003 Release 2, Standard x64 Edition with HP All-in-One Storage Manager Software [1TB SATA, 2TB SATA, and 584GB SAS models] |
---|
Administrationsfunktioner | Microsoft Management Console (MMC)-based user interface (also accessible via HTTPS); Remote system management via Remote Desktop or Telnet (Optional) HP Lights-Out 100c Remote Management Card |
---|
Kabinettype | Micro ATX Tower |
---|
Internt masselager | 4 x 146GB SAS 10K HDD |
---|
Størrelse | 41.6 x 50.1 x56.8 cm (16.39 x 19.72 x22.36 ") |
---|
Maks. antal processorer | 1 |
---|
Harddisk-controller | Smart Array E200/128MB Controller with BBWC |
---|
Ekstern storage-controller | Smart Array E200/128MB Controller with BBWC |
---|
Netværkskort | Embedded NC105i PCIe Gigabit Ethernet Server Adapter |
---|
Udvidelsessokler | 1 x full-height, half-length 32-bit/33MHz PCI at 3.3V slot; 1 x full-height, half--length PCIe x1 slot (x8 connector); 1 x full-height, full--length PCIe x1 slot (x8 connector); 1 x full-height, full-length PCIe x8 slot (occupied by Smart Array E200/128MB controller on 1TB SATA, 2TB SATA, and 584GB SAS models);1 x Lights-out 100c option slot |
---|
Lager-temperatur | -30-60 °C |
---|
Relativ luftfugtighed | 10-90 % |
---|
Operationel temperatur | 10 - 35 °C |
---|
Administrationsfunktioner | Telnet; Remote Desktop; MMC-based interface accessible via HTTPS; LO100c (optional) |
---|
Storage luftfugtighed | 5-95 % |
---|
Software til fjernstyring | Telnet; Remote Desktop; MMC-based interface accessible via HTTPS; LO100c (optional) |
---|
Beskrivelse | None |
---|
Redundante blæsere | N/A |
---|
RAW kapacitet | 2 TB |
---|
Antal samtidige brugere (lokalt - netværk) | 10-25 user(s) |
---|
Source data-sheet | ICEcat.biz |
---|