HP J9447A#ABB

PROCURVE 5406ZL-48G-POE+ SWITCHCPNT EN

Identificador:53547
Marca:HP
P/N:J9447A#ABB
EAN:0884962255209
Disponibilidad:
Stock:No Disponible
PROCURVE 5406ZL-48G-POE+ SWITCHCPNT EN
-
5775.69
* precio sin IVA  Informativo  Descatalogado

HP ProCurve 5406zl-48G-PoE+ Switch

PROCURVE 5406ZL-48G-POE+ SWITCHCPNT EN

Overview
The HP ProCurve Switch 5400zl Series consists of the most advanced intelligent edge switches in the HP ProCurve Networking product line. The 5400zl series includes 6-slot and 12-slot chassis and associated zl modules and bundles. The foundation for all of these switches is a purpose-built, programmable ProVision ASIC that allows the most demanding networking features, such as Quality of Service (QoS) and security, to be implemented in a scalable yet granular fashion. With a variety of Gigabit interfaces, integrated PoE on all 10/100/1000Base-T ports, 10-GbE capability, and a choice of form factors, the 5400zl switches offer excellent investment protection, flexibility, and scalability, as well as ease of deployment, operation, and maintenance.

Features
Management

﹠bull;﹠nbsp;Remote Intelligent Mirroring: mirrors selected ingress/egress traffic based on ACL, port, MAC address, or VLAN to a local or remote 8200zl/6200yl/5400zl/3500yl switch anywhere on the network


Connectivity

﹠bull;﹠nbsp;IPv6: IPv6 host: the switches can be managed and deployed at the edge of IPv6 networks; Dual stack (IPv4/IPv6): provides transition mechanism from IPv4 to IPv6; supports connectivity for both protocols; MLD snooping: forwards IPv6 multicast traffic to the appropriate interface; prevents IPv6 multicast traffic from flooding the network; IPv6 ACL/QoS: supports ACL and QoS for IPv6 network traffic.


Performance

﹠bull;﹠nbsp;High-speed/capacity architecture: 691.2 Gbps crossbar switching fabric provides intra- and inter-module switching with 480.3 million pps throughput on the purpose-built ProVision ASICs


Resiliency and high availability

﹠bull;﹠nbsp;Virtual Router Redundancy Protocol (requires Premium License): VRRP allows groups of two routers to dynamically back each other up to create highly available routed environments


Layer 2 switching

﹠bull;﹠nbsp;IEEE 802.1ad Q-in-Q (requires Premium License): increases the scalability of Ethernet network by providing a hierarchical structure; connects multiple LAN's on high-speed campus or metro network


Layer 3 services

﹠bull;﹠nbsp;UDP helper function: UDP broadcasts can be directed across router interfaces to specific IP unicast or subnet broadcast addresses and prevent server spoofing for UDP services such as DHCP


Layer 3 routing

﹠bull;﹠nbsp;Static IP routing: provides manually configured routing; includes ECMP capability

Garantía
Warranty: Lifetime warranty: for as long as you own the product, with next-business-day advance replacement (available in most countries)
Más información: ProCurve 5406zl-48G-PoE+ Switch
Productos relacionadosVer
Ficha técnica
ReferenciaHP J9447A#ABB
Latència1000 Mb: < 3.7 µs (FIFO 64-byte packets); 10 Gbps: < 2.1 µs (FIFO 64-byte packets)
Capacitat de commutació322.8 Gbps
tamany de direcció de la taula10000 entries
Plataforma de gestióProducts: HP ProCurve Manager (included); HP ProCurve Manager Plus; Access Methods: command-line interface; Web browser; configuration menu; out-of-band management (serial RS-232C)
protocols de xarxa suportatsRFC 1591 DNS (client); HTML and telnet management; IEEE 802.1ad Q-in-Q (Premium License); IEEE 802.1D MAC Bridges; IEEE 802.1p Priority; IEEE 802.1Q VLANs; IEEE 802.1s Multiple Spanning Trees; IEEE 802.1v VLAN classification by Protocol and Port; IEEE 802.1w Rapid Reconfiguration of Spanning Tree; IEEE 802.3ad Link Aggregation Control Protocol (LACP); IEEE 802.3af Power over Ethernet; IEEE 802.3x Flow Control; RFC 768 UDP; RFC 783 TFTP Protocol (revision 2); RFC 792 ICMP; RFC 793 TCP; UDLD (Uni-directional Link Detection); RFC 826 ARP; RFC 854 TELNET; RFC 868 Time Protocol; RFC 951 BOOTP; RFC 1058 RIPv1; RFC 1350 TFTP Protocol (revision 2); RFC 1519 CIDR; RFC 1542 BOOTP Extensions; RFC 2030 Simple Network Time Protocol (SNTP) v4; RFC 2131 DHCP; RFC 2453 RIPv2; RFC 2548 (MS-RAS-Vendor only); RFC 3046 DHCP Relay Agent Information Option; RFC 3576 Ext to RADIUS (CoA only); RFC 3768 VRRP (Premium License); RFC 4675 RADIUS VLAN ﹠ Priority; RFC 3376 IGMPv3 (host joins only); RFC 3973 Draft 2 PIM Dense Mode (Premium License); RFC 4601 Draft 10 PIM Sparse Mode (Premium License); RFC 1981 IPv6 Path MTU Discovery; RFC 2460 IPv6 Specification; RFC 2710 Multicast Listener Discovery (MLD) for IPv6; RFC 2925 Remote Operations MIB (Ping only); RFC 3019 MLDv1 MIB; RFC 3315 DHCPv6 (client only); RFC 3513 IPv6 Addressing Architecture; RFC 3596 DNS Extension for IPv6; RFC 3810 MLDv2 (host joins only); RFC 4022 MIB for TCP; RFC 4113 MIB for UDP; RFC 4251 SSHv6 Architecture; RFC 4252 SSHv6 Authentication; RFC 4253 SSHv6 Transport Layer; RFC 4254 SSHv6 Connection; RFC 4293 MIB for IP; RFC 4419 Key Exchange for SSH; RFC 4443 ICMPv6; RFC 4541 IGMP ﹠ MLD Snooping Switch; RFC 4861 IPv6 Neighbor Discovery; RFC 4862 IPv6 Stateless Address Auto-configuration; RFC 1213 MIB II; RFC 1493 Bridge MIB; RFC 1724 RIPv2 MIB; RFC 1850 OSPFv2 MIB; RFC 2021 RMONv2 MIB; RFC 2096 IP Forwarding Table MIB; RFC 2613 SMON MIB; RFC 2618 RADIUS Client MIB; RFC 2620 RADIUS Accounting MIB; RFC 2665 Ethernet-Like-MIB; RFC 2668 802.3 MAU MIB; RFC 2674 802.1p and IEEE 802.1Q Bridge MIB; RFC 2737 Entity MIB (Version 2); RFC 2787 VRRP MIB; RFC 2863 The Interfaces Group MIB; RFC 2925 Ping MIB; RFC 2328 OSPFv2 (Premium License); RFC 3101 OSPF NSSA; RFC 2474 DiffServ Precedence, including 8 queues/port; RFC 2597 DiffServ Assured Forwarding (AF); RFC 2598 DiffServ Expedited Forwarding (EF); IEEE 802.1X Port Based Network Access Control; RFC 1492 TACACS+; RFC 2865 RADIUS (client only); RFC 2866 RADIUS Accounting; Secure Sockets Layer (SSL); SSHv1/SSHv2 Secure Shell
Memòria i processadorGigabit Module: ARM9 @ 200 MHz; packet buffer size: 144 Mb QDR SDRAM; 10G Module: ARM9 @ 200 MHz; packet buffer size: 36 Mb QDR SDRAM; Management Module: Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 128 MB compact flash, 256 MB DDR SDRAM
RendimentUp to 240.2 million pps
Muntatge en rackMounts in an EIA-standard 19 in. telco rack or equipment cabinet (hardware included); horizontal surface mounting only
Dimensions W x D x H44.45 x 45.09 x 17.53 cm
Pes15.83 kg
Compliment de les normes de l'industriaEN: EN55024, CISPR 24; ESD: IEC 61000-4-2; 4 kV CD, 8 kV AD; Radiated: IEC 61000-4-3; 3V/m; EFT/Burst: IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line); Surge: IEC 61000-4-5; 1 kV/2 kV AC; Conducted: IEC 61000-4-6; 3V; Power frequency magnetic field: IEC 61000-4-8; 1A/m, 50 or 60 Hz; Voltage dips and interruptions: IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods; Harmonics: EN61000-3-2, IEC61000-3-2; Flicker: EN61000-3-3, IEC61000-3-3
Ports d'entrada i sortida4 open module slots; 44 RJ-45 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); Duplex: 10Base-T/100Base-TX: half or full; 1000Base-T: full only; Media type: Auto-MDIX; 4 open mini-GBIC (SFP) slots; 1 RS-232C DB-9 console port; Supports a maximum of 144 auto-sensing 10/100/1000 ports or 16 10-GbE ports or 96 mini-GBICs , or a combination
emissions pressió acústica Power: 57 dB, Pressure: 40.2 dB ISO 7779, ISO 9296 dB
Requisits d'alimentació110 -127 VAC / 200 -240 VAC; 50 /60 Hz
1 power-supply slots; 1 x J9306A, HP ProCurve 1500W PoE+ zl Power Supply
SeguretatCSA 22.2 No. 60950; UL 60950; IEC 60950; EN 60950
Altitud de funcionament> 10000 ft. 3 km.
Rang d'humitat15% to 95% @ 55ºC, non-condensing
Rang de temperatura (T-T)-40 - 70 °C
Interval de temperatura de funcionament (T-T)0 - 55 °C
Humitat d'emmagatzematge15% to 95% @ 65ºC, non-condensing
Compatibilitat electromagnèticaFCC Class A; EN55022/CISPR-22 Class A; VCCI Class A
Source data-sheetICEcat.biz
Opiniones de usuarios:
Su opiniónAñadir opinión
Valoración ☆☆☆☆☆ (Sin valoración)
Opiniones y comentarios, HP J9447A#ABB
product